As of April 12, 2011
| Organization | Requirements Standard No.*1 |
Cert. No. | Rating | Model: UL Style No. |
|---|---|---|---|---|
| UL | UL 2353 UL 1950-3e/IEC 60950, Annex U (UL 1411?UL 60950-1) |
E206440 OBJT2 (E188643,AVLV2)*2 (E157568,OCDT2)*2 |
1000 Vrms TEX-E B(130°C)*3TEX-ELZ, TEX-ECEW3 E(120°C) |
TEX-E (Style 10348)*2 TEX-ELZ (Style 10349)*2 TEX-ECEW3(Style 10389)*2 |
| CSA (NRTL/C) |
CAN/CSA 60065-03 incl. AM1 ANSI/UL std No. 60065-2007 CAN/CSA-C22.2 No. 60950-1-07 ANSI/UL std No. 60950-1-2007 |
Master Contract 185274*4(LR104155) |
1000 Vrms 120°C(E) |
TEX-E TEX-ELZ TEX-ECEW3 |
| TUV Rheinland |
EN 60950-1:2006+A11, IEC 60950-1:2005 DIN EN 60950-1:2006+A11 EN 60065:2002+A1+A11 IEC 60065:2001+A1 |
T9251520 | 1000 Vrms TEX-E B(130°C)TEX-ELZ, TEX-ECEW3 E(120°C) |
TEX-E TEX-ELZ TEX-ECEW3 |
| BSI | BS EN 60065:2002, IEC 60065:2001 Subclauses 14.3.4/14.3.5 (8.8 and 8.17), 10.3 and Annex H; and 20.1.4 BS EN 60950-1:2006, IEC 60950-1:2005 Subclause 2.9.1 (with 2.9.2 and 5.2.2) and 2.10.5.12 (Annex U); and 4.7.3.4 (A.2 excluding A.2.4, but including A.2.7) |
KM 36738 | 1000 Vrms 120°C |
TEX-E |
| NEMKO | Annex U of EN 60950-1:2006; A11 and Annex H of EN 60065:2002; A1; A11 | P10212368 | 1000 Vrms E(120?) |
TEX-E TEX-ELZ TEX-ECEW3 |
| VDE | DIN EN 60950-1:2006 +A11 (VDE0805Teil1+A11): 2009-11; EN60950-1:2006+A11:2009-03, IEC60950-1 (ed.2) |
VDE-Reg.-Nr.6735 | 1000 Vpeak 700 Veff Max. 500kHz Class E and B |
TEX-E |
- TEX-E series are the insulated winding wire having Reinforced Insulation complying with subclause 2.10.5.4, Annex U of IEC 60950 3rd, IEC 60950-1 and subclause 8.17, Annex H of IEC 60065 7th. Normal Withstand Test Voltage is 3kVrms for 1 minute. TEX-E series also complies with 6kVrms for 1minute as a twisted pair.
- UL changed the category of TEX-E series from OCDT2, AVLV2 to OBJT2. Therefore, TEX-E wires acquired new UL File No and the category. The product covered by E206440 (OBJT2) is quite the same as the product covered by E157568 (OCDT2) and E188643 (AVLV2). These product can be used compatibly each other.
- When operation temperatures of the wound components exceed Class A (105°C), it is required in accordance with appropriated Insulation System UL 1446/IEC 61857 regardless of temperature rating of each materials/wires.
- Numbering system of CSA was revised at 2000. Legacy File number is compatible.
Note
TEX-E: Standard type, TEX-ELZ: Litz wire type, TEX-ECEW3: Self-bonding type